It is designed for cooling the one CO2 glass laser tube under 130W/150W of the laser engraving and cutting machine. Under normal circumstance, the new intelligent temperature controller does not need to adjust the controlling parameters. It will self-adjust controlling parameters according to room temperature to meet cooling demands.
Mainly used to have the heat generated during the laser device working that gone through the refrigerating cycle in compressor refrigeration system and eventually transferred to the air. The water temperature is able to be adjusted. There are 2 specifications as. 1 water outlet / inlet and dual water outlet / inlet.
Applicable to cool single laser glass tube. Economic cooling equipment, easy to install and operate, compact and easily movable. Our industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control. Under intelligent mode, the water temperature is adjusted according to ambient temperature.
With this 1 key solution, customers no longer need to worry about water temperature adjustment of seasonal changes. Fill the water tank with purified water. Connect the water inlet of the water tank to the water outlet of the laser machine and connect the water outlet of the water tank to the water inlet of the laser machine. Open the package to check if the machine is intact and all the necessary accessories are completed. Open the injection port to feed cooling water.
Observe water level gauge while adding water slowly, be careful not to have water overflowed! For the cooling of carbon steel equipment, water should be added with an appropriate amount of anti-corrosion agentia. Working in cold north area, its better to use noncorrosive antifreeze fluid. According to system conditions, please well connect water inlet and outlet pipe. Plug in, turn on the power switch. Do not start up without water in the tank! (1) Circulation pump of the chiller starts working. Operating for the first time may produce bubbles in the pipe, which occasionally leads to flow alarming. In such case, it will go back to normal after running for a few minutes. (2) After the first boot, please immediately check whether the water pipe leaks. (3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters. (4) As it takes a longer time to start the compressor and other components, the time you take might range from seconds to minutes, please do not turn the power off and on again frequently.Check the water level in the water tank. The first startup of the new chiller empties the air in the water pipe, leading slightly water level decline. In order to keep the water level in the green area, its allowed to replenish adequate water.
Please observe and record the current water level and inspect it again after the chiller has been running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage. Adjust parameters of temperature controller.CW-5200 series use an intelligent thermostat. Normally users do not need to adjust it. If it's really necessary, please refer to Operating status and parameters adjustment. Cooling water must be kept empty when cooling machine has been not in use for long or in transport.
It is strictly forbidden to plug and run the cooler without feeding water. Cooler should be placed in a well-ventilated, dry environment away from heat sources.
Please keep at least 30cm from obstructions to the air outlet which is in the back of the cooler, and leave at least 10cm between obstructions and air inlets of two sides. To protect laser tubes , the radiator fan of cooler will suspend to work when water temperature is too low , and it will restart to run when water temperature rises back to accceptable range. To ensure good heat dissipating, please open the lid to clean the dirt regularly.
Working in cold north area, it is better to use noncorrosive antifreeze fluid. E1- Over high room temperature. E2- Over high water temperature. E3- Over low water temperature. E4- Room temperature sensor failure. E5- Water temperature sensor failure. When alarm occurs, the error code and the temperature will be alternately displayed. In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display. Remains until the alarm condition is eliminated. Flow alarm and output ports. In order to guarantee that the equipment will not be damaged when cooling water circulation is out of control, CW-5200series chillers possesses an unique low flow alarm protection.The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V. Energy saving, long working life and simple operation. Different models according to local voltage and frequency. With completed water flow and over high temperature alarm functions. Professional forced air-cooled radiator, high heat dissipating capacity and not easy to be blocked.
Equipped with alarm output port, can quickly protect sensitive components. Multiple power specifications; CE approval; RoHS approval. Water is available for a long time used. Real-time temperature monitoring, accurate knowledge of heating devices working condition.
High cost performance, low failure rate. 1400W cooling capacity; optional environmental refrigerant. ±0.3°C precisely temperature control. The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions.
Multiple alarm functions: compressor time-delay protection, compressor overcurrentprotection, water flow alarm and over high / low temperature alarm. Optional heater and water filter. Compressor Power: 0.68KW, 0.93HP. Refrigerating Capacity: 5186Btu/h, 1.52KW, 1307Kcal/h. Refrigerant: R-22 / R-134a / R-410a.
Refrigerant Charge: 12.3oz / 350g. Precision: ±32.54 / 0.3. Maximum Pumping Lift: 11 Yards / 10M.Inlet and Outlet: External 0.4in / 10mm brass connector. Packing Dimensions: 28.3 17.3 24.4in / 720440620mm (LWH). Protection: Over current protection for compressor, flow alarm, over temperature alarm.
1 × CW-5200DG Water Chiller Machine. 1 × Alarm Signal Output Plug. We believe that it is our vision and mission to provide innovative products with best service and competitive price to satisfy you.
Our goal is to make sure that you can find exactly what you are looking for and make it easy for you to place your orders. California Warehouse: 18501 Arenth Ave, City of Industry, CA 91748. 300 W Airtex Blvd, Suite 200, Houston, TX 77090. 2125 Gateway Blvd, Hebron, KY 41048.
1000 High Street, Perth Amboy, NJ 08861. If you need to return, please check twice to confirm the item not work and contact our customer service representative, let us know the detailed problem and send us some pictures for confirmation.
Please make sure that item has NO man-made sabotage. Used items will not be accepted for return. All emails will be responded to within. Special circumstances will be listed clearly in the listing.
Please do check everything carefully after you received the parcel, any the damage except DOA (Dead-On-Arrival) would not be covered if it's your fault. A: The item ships from Rancho Cucamonga, CA, United States. A: Please log on your account. Q: How do I return an item? Please contact our customer service before you return an item.
The item "CW-5200 Industry Water Chiller for CO2 Laser Engraving Cutting Machine 110V US" is in sale since Monday, October 9, 2017. This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Medical & Lab Equipment, Devices\Water Baths, Circulators & Chillers". The seller is "yufann8_6" and is located in Perth Amboy, New Jersey.
This item can be shipped worldwide.