Line first electrode connected, (+, -) Do not pick the wrong pole. Cooling water pipe connected, the water connection from the anode, cathode and down into the water on the principle meet, and the interface is not leaking. Must store enough water in the water before use, must weather bubble through water in the water-cooled pipe before use (before use each time you have to look). Automatic detection devices are recommended to join in the net but the laser tube water system to prevent the laser tube without water while at work due to overheating fault Troubleshooting: First, the moment is not deep: 1. Cut is not deep: check the supporting point of the laser tube is reasonable, whether the light intensity is set too small, the optical path is offset, the focal length is correct, whether ytterbium sheet surface scratches and dirt, if the flow of cooling water flow pressure normal , no more than a few problems on check light outlet lens inside the laser tube for scratches and dirt, if you are normal, then it is the laser tube itself, the quality problem.
Emitting a while before the moment is not deep: this problem is to test the support point of the laser tube is reasonable, the water temperature exceeds 30 degrees, the lens is heat at work, whether the flow of cooling water flow pressure is normal, if the cooling water clean, above normal then check the laser tube Second, the high voltage ignition and discharge: 1. Check around the high pressure head there and moist dirt away from the metal part of the machine is too close; the other is the laser power high-voltage connector device is falling from the seat, and whether an internal high-voltage connector device disconnection and destruction. If above normal, then so is the quality of the laser tube itself is a problem. Third, the laser tube broken, cracked, water head off: 1.
Water temperature is controlled in the range of 25 -30 , the cooling water can not ice cold regions, especially after laser shutdown, may not allow the cooling water retention in the laser tube. Whether luminous work under the control of the water protection; (test will not be as luminous water off and emit light or not) 3. There are no water pipes will fight the demolition of the phenomenon.
Whether there will be bubbles within the laser tube. Water pressure is normal; if the direction of flow low prices. Package include: 1 x 40W Laser Tube.
International buyers please note: a. The item "40W CO2 Laser Tube Metal Head Glass Pipe 700mm For Cutting Engraving Machine" is in sale since Monday, June 05, 2017. This item is in the category "Business & Industrial\Healthcare, Lab & Life Science\Lab Equipment\Lab Lasers & Photonics".
The seller is "mhestore2009" and is located in HK. This item can be shipped worldwide.